Moore Industries

Alarm Trips

Alarms Image for LP

Industrial Alarm Trips Made to Protect your Process

At Moore Industries, we understand the critical importance of maintaining safety and operational efficiency in your industrial processes. Our Alarm Trips are designed to provide precise, reliable monitoring, and alert control systems, ensure smooth operation, or directly prevent accidents. With a rugged and reliable design and advanced features, our Alarm Trips are the ideal solution for a wide range of applications including:

  • Provide On/Off Control
  • Warn of Trouble when a Monitored Process Signal Falls Outside of a Selected High and/or Low Limit
  • Provide Emergency Shutdown 
  • SIL 2/3 Capable and exida Certified options
  • User-Friendly and Easy-to-Setup 

View All Alarm Trips

SLA-2023-08-LookRight
SLA Functional Safety Multiloop Logic Solver and Alarm

The SLA is a versatile multiloop and multifunctional Safety Logic Solver and Alarm that is engineered to deliver optimal performance for safety loops in hazardous process conditions. It bridges the gap between single-loop logic solvers and costly safety PLCs, offering a range of functionalities to ensure the utmost safety and control in your operations. The SLA is exida approved and SIL3-capable and features 16 alarms to optimize voting logic. Its user-friendly FDT/DTM programming includes easy-to-understand drop-down menus, checkboxes, and Excel-like math equations. It communicates over MODBUS/TCP and MODBUS RTU, with HART pass-thru capabilities, and includes an embedded web server that offers "read-only" browser access for enhanced security, and so much more!

Get the Data Sheet or Visit the Catalog

 

spa2

SPA2 Programmable Limit Alarm Trip

The universal SPA2 Programmable Limit Alarm Trips provide on/off control, warn of unwanted process conditions, alarm on rate-of-change, and provide emergency shutdown. Very versatile, they accept a signal input from transmitters, temperature sensors, and a wide array of other monitoring and control instruments including current and voltage signals, 23 RTD types, 9 thermocouple types, resistance and potentiometer devices, and direct millivolt sources. 

Get the Data Sheet or Visit the Catalog

 

STA-hlprgSTA Functional Safety Limit Alarm Trip

Part of the Moore Industries FS Functional Safety Series, the SIL 3 capable and exida® certified STA Safety Trip Alarm performs as a logic solver and acts on potentially hazardous process conditions; warns of unwanted process conditions; provides emergency shutdown; or provides on/off control in Safety Instrumented Systems (SIS) and traditional alarm trip applications. The 4-wire (line/mains-powered) STA models accept a signal input from transmitters, temperature sensors, and a wide array of other monitoring and control instruments including: current and voltage signals, temperature (RTD and T/C) sensor inputs, resistance and potentiometer devices, and direct millivolt sources

Get the Data Sheet or Visit the Catalog

 

www.miinet.comimagesproductsSPA2IS-din

SPA2IS Associated IS Programmable Limit Alarm Trip

The universal SPA2IS Programmable Limit Alarm Trips provide on/off control, warn of unwanted process conditions, alarm on rate-of-change, and provide emergency shutdown. Very versatile, they accept signal inputs from transmitters and temperature sensors that are located in hazardous areas where the method of protection implemented by the plant or facility is Intrinsic Safety. Normally such installations would require the additional use of an intrinsically-safe barrier. The SPA2IS, however, includes intrinsically-safe field connections which provide the necessary protection typically afforded by a galvanically isolated intrinsically-safe barrier. The SPA2IS accepts a wide array of inputs.

Get the Data Sheet or Visit the Catalog

 

 


NCS-MAANCS NET Concentrator System with Multipoint Analog Alarm

The Multipoint Analog Alarm -MAA option for the Moore Industries NCS NET Concentrator System provides the ability to implement simple or dynamic alarming schemes without being a PLC programmer. A full NCS station with the -MAA option can have as many as 60 inputs, 32 alarms, and eight physical relay outputs. Each of the 32 alarms can have a single input and a single relay output. Each of the eight relay outputs can be activated by a single alarm, multiple alarms or by all 32 alarms if desired. Minimum hardware configuration includes an EMM Ethernet MODBUS Module, ROM Remote Output Module, and any NCS Input module. 

Get the Data Sheet or Visit the Catalog

 

 

ECA Alarm Trip-no bkgECA Current and Voltage Limit Alarm Trip

The ECA DIN-style Alarm features a solid metal housing that stands up to the continual rigors of process control and factory automation applications. Rugged and reliable, the 4-wire (line-powered) ECA is the low-cost solution when alarm trip outputs are needed to indicate high or low process conditions. Available models accept current and voltage input from field transmitters, transducers, and other process instruments. When the input falls outside of a pre-set limit (user configurable), the ECA provides contact closure outputs ideal for indicating a high and/or low condition via a bell, buzzer, light or other annunciating device. 

Get the Data Sheet or Visit the Catalog

 

 

 

330R2_Series_left330R2 1/8 DIN Process and Temperature Panel Meter & Alarm

The 330R2 digital process and temperature panel meter is one of the most versatile meters on the market. Its universal input and dual process relays will satisfy a wide variety of process and temperature applications. Housed in a 1/8 DIN enclosure, the meter can be field programmed to accept process voltage (0-5V, 1-5V, 0-10V, ±10V) and current (0-20mA, 4-20mA, ±20mA) inputs, 100 Ohm RTDs, and the four most common thermocouples. 

Get the Data Sheet or Visit the Catalog

 

Have questions or need a quote? Fill out the form below!